Magnet Wire Thermal Class

Thermal classes 155 to 240 explained

Magnet wire insulation class, or thermal class, is a classification of the finished wire’s thermal endurance under the applicable product standard. It specifies a minimum temperature index, determined by thermal endurance testing to IEC 60172 (or ASTM D2307 under NEMA MW 1000). It does not by itself set the allowable operating temperature of a winding.

This guide covers what a thermal class establishes, how it relates to the insulation system and the machine rating, and how to choose one. For enamel chemistries and film build, see magnet wire insulation types.

Jingda magnet wire by thermal class

Jingda supplies magnet wire in five thermal classes. Pick a class to go to the matching product.

155Letter FPEW · copperalambre de cobre esmaltado
180Letter HUEW · EIWalambre de cobre esmaltado
200Letter NEI/AIW · copper200 class enameled copper wire
220Letter REI/AIW · aluminum · AIW · copperaluminum magnet wire
240No IEC 60085 letterPIW · copperpolyimide magnet wire
Thermal class, standard designation and Jingda product
Clase térmicaIEC 60085 letterInsulation (see tipos)Typical standard designationsJingda product
155FPEW, copperNEMA MW 5-Calambre de cobre esmaltado
180HUEW; EIWIEC 60317-51, IEC 60317-8 · NEMA MW 82-C, MW 30-Csolderable magnet wire; alambre de cobre esmaltado
200NEI/AIW, copperIEC 60317-13 · NEMA MW 35-C, MW 73-C200 class enameled copper wire
220REI/AIW, aluminum; AIW, copperAluminum: NEMA MW 35-A / MW 73-A; general requirements IEC 60317-0-3; tests per IEC 60851. Copper: IEC 60317-57; NEMA MW 81-Caluminum magnet wire; alambre de cobre esmaltado
240NonePIW, copperIEC 60317-46 · NEMA MW 16-Cpolyimide magnet wire

Each row is a wire classification. The class a winding or machine may carry is set by the system evaluation and the equipment standard (see below). Class, construction and standard for every grade are stated on the product datasheet.

What a magnet wire thermal class is

How the class is established

Each applicable IEC 60317 part and NEMA MW type specifies a wire construction and the thermal class it must meet. The temperature index is determined per IEC 60172: specimens of the finished wire are aged in air at several elevated temperatures and checked periodically with an AC proof voltage test. The time-to-failure results are then extrapolated to the reference life set by the standard. ASTM D2307 is the corresponding thermal-endurance test method used with NEMA MW 1000; specimen preparation and reporting must follow the cited method.

The test is run on the wire alone, without slot liners, varnish or the other materials of a real winding. That is why the result describes the wire, and why IEC 60172 presents the data as input for selecting wire for further evaluation of insulation systems.

Three points to carry into a design review

A class is not an operating temperature.Allowable operating conditions come from the equipment’s thermal design, evaluated at the hot spot.
Wire class does not set system class.A system’s class cannot be read off the highest or lowest label among its materials; compatibility between them matters as much as any single rating.
A higher class is a higher test requirement.It does not automatically give better winding performance or a higher machine rating. The correct class is the one the application requires and the system supports.

Wire class, insulation-system class and machine rating are three different things

Wire thermal class, insulation-system class and machine rating describe three different objects, each established by its own evaluation. Most thermal class confusion comes from reading one as another. Wire thermal class is one input to system evaluation.

Three objects, three evaluations
ObjectWhat it describesWhat establishes it
Clase térmica del alambreThe finished wire insulationThermal endurance testing to the product standard (IEC 60317 / NEMA MW 1000), method IEC 60172
Insulation system (EIS) classWire, slot liner, phase insulation and varnish togetherEvaluation of the complete system per IEC 60085 / IEC 61857 / UL 1446
Equipment ratingThe motor, generator or transformer as builtIEC 60034-1 / NEMA MG 1 for rotating machines; the IEC 60076 series for power transformers, resting on the evaluated system

The standards evidence chain

  1. 1 · Wire productWhat is this wire, and what must it meet?IEC 60317 series · NEMA MW 1000
  2. 2 · Test methodsHow are the temperature index and other properties determined?IEC 60172 · IEC 60851 series
  3. 3 · Insulation systemHow is the complete system classified and evaluated?IEC 60085 · IEC 61857 · UL 1446
  4. 4 · EquipmentWhat may the equipment be rated and marked?IEC 60034-1 · NEMA MG 1 · IEC 60076 series

Each level answers a different question, and no level can answer for another. IEC 60085 makes the same point from the system side: a thermal class assigned to an insulating material does not carry over to that material’s use in a system.

How to select a thermal class

Select a class from the application’s requirements, then confirm it with documentation and winding trials.

  1. Understand the operating environment. What temperature and duty conditions will this winding actually see?
  2. Evaluate hot-spot temperature. Is the design working from average winding temperature or from the actual hot spot?
  3. Review the complete insulation system. How has the combination of components been evaluated, and what does that evaluation cover?
  4. Select the wire thermal class. Does the requirement justify this class, or is it margin the system cannot use?
  5. Verify supplier documentation. Can the designation, standard and certification scope be confirmed from documents in hand?

Decision inputs: hot-spot temperature; required service life; ambient and cooling arrangement; duty cycle; voltage waveform (inverter duty adds stress); EIS coverage available at each class; film build and slot fill; winding-trial results on the candidate wire.

Class 200 or Class 220?

The higher number is not the safer default. Start from hot-spot temperature, life target, duty and waveform, check which classes the evaluated insulation system covers, and confirm with winding trials. In the Jingda range the two classes also differ in construction: Class 200 includes EI/AIW copper wire, while Class 220 includes EI/AIW aluminum wire and AIW copper wire.

When is Class 240 the right call?

Class 240 wire should be considered when the application requires its thermal endurance and the complete insulation system has been evaluated for the intended operating conditions. Confirm the product designation and termination method on the datasheet, then complete sample and winding-trial validation before release. PIW is not intended for direct soldering, so plan termination early.

Does a higher wire class raise the machine rating?

Not by itself. A machine rating rests on the evaluated insulation system and the equipment standard; the wire is one input among several. Changing only the wire does not establish a higher rating; a new rating needs its own system evaluation.

Thermal class and film build are separate lines of the specification

Film build (IEC Grade 1, 2 and 3; NEMA designations such as Single, Heavy and Triple) specifies coating thickness, not thermal class. Specify class and build separately; see magnet wire insulation types and film build for the detailed comparison.

Class H and the letter classes

Class H is the IEC 60085 letter for thermal class 180. Class H magnet wire normally means wire with a thermal class of 180; in the Jingda range that includes EIW (IEC 60317-8, NEMA MW 30-C) and UEW (IEC 60317-51, NEMA MW 82-C). For chemistry details, see magnet wire insulation types.

IEC 60085 thermal classes and letters
Clase térmica90105120130155180200220250+
LetterYAEBFHNR—

The numeric form is the primary designation; the letter may be added in parentheses, as in Class 180 (H), and can stand alone where space is short, such as on a nameplate. That is why the industry still says “Class H”: motor nameplates, drawings and machine standards identify insulation systems by class. A Class H motor carries a Class H insulation system. The wire inside it can be Class 180 or higher, depending on what the system evaluation covers.

Selection checklist

A specification is complete when every line below can be answered from documents in hand and validated on samples.

Thermal class specification checklist
#VerifyEvidence
1Application requirement and hot-spot temperature definedThermal design record
2Required service life, duty cycle and voltage waveform statedEquipment specification
3Wire designation confirmed against IEC 60317 / NEMA MW 1000Product datasheet
4Insulation construction and film build confirmedProduct datasheet
5EIS coverage at the selected class confirmedEIS evaluation record
6Certification scope checked where claimedUL Product iQ
7Winding trial and sample validation completedTrial report, sample lot

Also verify, as the application requires (IEC 60851 series): conductor material, dimensional tolerances, breakdown voltage, heat shock, flexibility and adherence, abrasion, chemical or refrigerant compatibility, and pulse and partial discharge requirements for inverter duty.

Frequently asked questions

What is magnet wire insulation class?

It is the thermal class of the finished wire insulation: a minimum temperature index established by thermal endurance testing to IEC 60172 or ASTM D2307, under IEC 60317 or NEMA MW 1000. Common classes are 155, 180, 200, 220 and 240.

¿Qué es el alambre magneto clase H?

Class H is the IEC 60085 letter for thermal class 180. Class H magnet wire is wire rated Class 180, such as EIW (IEC 60317-8, NEMA MW 30-C) or UEW (IEC 60317-51, NEMA MW 82-C).

Is Class 200 better than Class 180?

Class 200 wire meets a higher thermal-endurance requirement than Class 180 wire. Whether it is the better choice depends on the application and its suitability for the evaluated insulation system.

Does thermal class equal operating temperature?

No. Thermal class is a classification of the wire insulation from thermal endurance testing. Allowable operating temperature comes from the equipment’s thermal design, evaluated at the hot spot, and from the rating of the complete insulation system.

How is magnet wire thermal class tested?

Per IEC 60172: finished-wire specimens are aged in air at several elevated temperatures, checked periodically with an AC proof voltage test, and the results extrapolated to a reference life. ASTM D2307 is the corresponding method used with NEMA MW 1000; follow the specified test method for the product designation.

Can I raise a motor’s rating by using higher class wire?

Not by itself. A motor’s rating rests on its evaluated insulation system and the equipment standard, such as IEC 60034-1 or NEMA MG 1. A higher-class wire does not establish a higher rating without a new system evaluation.

Request a quote or a datasheet

Send your application requirement and hot-spot temperature; Jingda answers within 1 business day. MOQ 600 kg per specification; standard lead time 30 days; FOB by default.

Tongling Jingda Special Magnet Wire Co., Ltd. has manufactured enameled wire since 1990 to IEC 60317 and NEMA MW 1000, under an ISO 9001 quality system. UL Recognized constructions are available; the UL status of a specific grade is confirmed on request. The full range is on our alambre esmaltado page.